The significance of supervised monitoring modules utilized in management and monitoring of extinguishing systems

In many places from chemistry laboratories to industrial services, in order to ensure the safety of life and property in opposition to a potential fire hazard, extinguishing techniques are used along with detection and alarm techniques. It can be extraordinarily essential that the extinguishing methods put in may be triggered by the fireplace extinguishing management panel, in order to remove a attainable hearth with early intervention.
In order to fulfill these needs, and with 35 years of sectoral information and experience, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel operating in accordance with the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant performance of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing course of to be started manually and remotely; and

to ensure that the extinguishing course of could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced using surface-mount technology and are aimed toward making the automation of the extinguishing system and fireplace and gasoline detection system excellent.
Image copyright: Mavili

Mavili Elektronik develops its merchandise by all the time contemplating the wants of the installation. In circumstances that require the integration of the extinguishing system with the intelligent addressable fire detection system, it offers options through the monitoring modules that also have a ‘supervised’ possibility.
Supervised monitoring ไดอะแฟรม play an necessary role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or quick circuit in the wiring between the contact monitoring modules and the peripheral methods can cause disruption of the triggering, with potentially important consequences. For this purpose, when choosing monitoring modules, it must be taken into account that they’ve supervised options.
Image copyright: Mavili

Since Maxlogic intelligent addressable fire detection and alarm management panels are constantly communicating with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 standards, it makes it simpler to watch situations such as open circuits and quick circuits which will occur within the system. Many duties could be carried out within the hearth extinguishing installation, such as the management and monitoring of all valves that can interrupt the move of water, water flow alarm switches, pressure swap, and electrical or diesel fire pumps.
By adding two contact monitoring modules to 2 separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to manage errors and the opposite to regulate the fireplace state of affairs, monitoring and management of the extinguishing system via an intelligent addressable fire detection and alarm system can be performed effectively.
For more information, go to www.mavili.com.tr/en